Items |
TSBSCB06 TSBSC Shock Relay for Overload Protection |
TSBSCB34 TSBSC Shock Relay for Overload Protection |
TSBSCB60 TSBSC Shock Relay for Overload Protection |
TSBSCS06 TSBSC Shock Relay for Overload Protection |
TSBSCS34 TSBSC Shock Relay for Overload Protection |
|||||
Type | N/A All-in One Type | N/A All-in One Type | N/A All-in One Type | N/A Panel Mount Type | N/A Panel Mount Type | |||||
Max Amperage | N/A 05 | N/A 30 | N/A 60 | N/A 100 | N/A 200 | |||||
Amperage Range | N/A 0.15 to 6.4 A | N/A 3 to 14 A | N/A 10 to 60 A | N/A 12 to 100 A | N/A 24 to 200 A | |||||
230 Volt Motor HP | N/A 1/16 to 2 hp | N/A 1 to 10 hp | N/A 5 to 25 hp | N/A 5 to 40 hp | N/A 10 to 75 hp | |||||
460 Volt Motor HP | N/A 1/8 to 5 hp | N/A 2 to 25 hp | N/A 10 to 50 hp | N/A 10 to 75 hp | N/A 20 to 150 hp | |||||
Mounting Type | N/A Panel mounting with remote display option | |||||||||
Electrical Life | N/A Activation 100,000times at rated load cycles | |||||||||
Ambient Humidity | N/A 30 to 85%RH (No dew condensation) % | |||||||||
Start Time [Min] | N/A 0.2 s | |||||||||
Start Time [Max] | N/A 12.0 s | |||||||||
Shock Time [Min] | N/A 0.2 s | |||||||||
Shock Time [Max] | N/A 0.5 s | |||||||||
Operation Frequency | N/A 20 to 200 Hz | |||||||||
Maximum Motor Voltage | N/A AC600V 50/60Hz | |||||||||
Operation Power | N/A 100 to 240 VAC +/- 10%, 50/60 Hz | |||||||||
Current detection accuracy | N/A +/- 5% (In case of commercial power source) | |||||||||
Time detection accuracy | N/A +/- 5 % | |||||||||
Under current | N/A 0.2 to 5 s | |||||||||
Lock when starting up | N/A Set at 2 to 8 times of overcurrent setting value (OFF: No action) Trip after Star t time + 0.2s when star ting up. | |||||||||
Lock when operating | N/A Set at 1.5 to 8 times of overcurrent setting value (OFF: No action), trip at 0.2 to 5s. | |||||||||
Phase-reversal | N/A Trip within 0.15s, (OFF: No action) | |||||||||
Phase loss | N/A Trip at 0.5 to 5s (OFF: No action) | |||||||||
Imbalance | N/A Trip at 1 to 10s (OFF: No action) when setting at 10 to 50% | |||||||||
Alarm | N/A Output when A, F and H are set (OFF: No action) | |||||||||
Running hour | N/A Trip when 10 to 9990hr is set (OFF: No action) | |||||||||
Fail-safe | N/A Activated when setting ON (Conducting normally: Excited, Trip: Non-excited) | |||||||||
Rated load | N/A 3A, 250VAC | |||||||||
Minimum allowable load | N/A DC24V, 4mA | |||||||||
Contact arrangement | N/A OC:1c,AL/UC/TO:1a | |||||||||
Self-holding | N/A E-r: Manual release or reset of power source, H-r: Only manual release | |||||||||
Auto-reset | N/A A-r: Auto-reset and set the return time at 0.2s to 20min | |||||||||
Analog output | N/A Analog output 4 to 20mA DC Output (OFF: No action) Allowable load resistance: 100O and below | |||||||||
Communication output | N/A RS485/Modbus | |||||||||
Insulation between case and circuit | N/A DC500V, 10MO | |||||||||
Dielectric strength voltage between housing-circuit | N/A 2000VAC 60Hz 1min. | |||||||||
Dielectric strength voltage between relay contacts | N/A 1000VAC 60Hz 1min. | |||||||||
Location | N/A Indoors, where it will not get wet | |||||||||
Ambient temperature | N/A -20 to 60 ºC | |||||||||
Ambient humidity | N/A 30 to 85%RH (no dew condensation) | |||||||||
Altitude | N/A 2000 m | |||||||||
Atmosphere | N/A No corrosive gas, oil-mist or dust | |||||||||
Vibration | N/A 5.9 m/s² | |||||||||
Power consumption | N/A 7.0 VA | |||||||||
Weight | N/A 0.30 kg | |||||||||
|